This is the mail archive of the
ecos-discuss@sources.redhat.com
mailing list for the eCos project.
Re: odd serial input bug in redboot 095308 20010607 on iP
- To: David Bliss <david at ytterby dot dbsi dot org>
- Subject: Re: [ECOS] odd serial input bug in redboot 095308 20010607 on iP
- From: Gary Thomas <gthomas at cambridge dot redhat dot com>
- Date: Fri, 08 Jun 2001 09:47:05 -0600 (MDT)
- Cc: ecos-discuss at sources dot redhat dot com
- Organization: Red Hat, Inc.
Can you try this experiment for me?
Cold reset the unit. Presumably, the serial won't be working, but
don't touch it or the touch screen. After a few seconds, the LCD
should blank out. Then try typing on the serial. Does the LCD
come back on?
Another thing - do you have hardware handshaking (flow control) turned
off? I've found this necessary, at least on my Linux machines.