This is the mail archive of the
ecos-discuss@sourceware.org
mailing list for the eCos project.
Re: ping problem
Hi Andrew,
Sorry for the second mail. Our mail server blocks mails for groups, so I
have sent one more and asked sysadmin to forward it.
In the "Basic network framework" of configuration tool
INET Support
TFTP(RFC - 1350) Support
Use full DHCP instead of BOOTP
the above three are checked
In "initialization option for 'eth0' "
I have checked "address Setups for eth0" and filled in following values:
IP Address for 'eth0' 192.168.0.10
Network mask address for 'eth0' 255.255.255.0
Broadcast address for 'eth0' 0.0.0.0
gateway/router IP address for 'eth0' 0.0.0.0
Server IP address for 'eth0' 192.168.0.100
init_all_network_interfaces() returns the following
[cyg_net_init] Done
Start client server test /* start of my application */
BOOTP[eth0] op : REPLY
htype : ethernet
hlen : 6
hops : 0
xid : 0x0
secs : 0
flags : 0x0
hw_addr : 00:50:ba:d8:fc:fc
client IP : 192.168.0.10
my IP : 192.168.0.10
server IP : 192.168.0.100
gateway IP: 0.0.0.0
options:
subnet mask : 255.255.255.0
IP broadcast : 0.0.0.0
gateway : 0.0.0.0
Initialization of network interfaces done /* Application specific */
socket created
bind successful
Trying to accept...
If I run client from Linux PC( IP is 192.168.0.100) it says
connect: No route to Host
Broken Pipe.
Regards,
Madhava S
----- Original Message -----
From: "Andrew Lunn" <andrew@lunn.ch>
To: "Madhava Reddy S" <madhava.s@globaledgesoft.com>
Cc: <ecos-discuss@sourceware.org>
Sent: Tuesday, January 31, 2006 1:06 PM
Subject: Re: [ECOS] ping problem
On Tue, Jan 31, 2006 at 09:23:06AM +0530, Madhava Reddy S wrote:
Hi All,
I am working on i386 target.
I have a problem.
I have compiled eCos with Redboot and booted the target.
I was able to do telnet also.
I have created a new project with "net" option enabled and wrote a sample
client server application downloaded the exe to target using serial port.
When i run the server on target and client on Linux PC clent says broken
pipe.Server is failing at accept.
I tried to ping to target.
After downloading exe to target I am not able to ping to target so it
fails
at accept.
Is this the correct way to test or do i need to enable any option in my
configuration.
Please don't post the same message twice in quick sucession. It will
not help you get answers.
How do you configure the IP addresses? What output do you get from
init_all_network_interfaces()?
Andrew
--
Before posting, please read the FAQ: http://ecos.sourceware.org/fom/ecos
and search the list archive: http://ecos.sourceware.org/ml/ecos-discuss
This e-mail contains PRIVILEGED AND CONFIDENTIAL INFORMATION intended solely for the use of the addressee(s). If you are not the intended recipient, please notify the sender by e-mail and delete the original message.Global Edge Software Ltd has taken every reasonable precaution to minimize this risk, but is not liable for any damage you may sustain as a result of any virus in this e-mail. You should carry out your own virus checks before opening the e-mail or attachment. Global Edge Software Ltd reserves the right to monitor and review the content of all messages sent to or from this e-mail address
--
Before posting, please read the FAQ: http://ecos.sourceware.org/fom/ecos
and search the list archive: http://ecos.sourceware.org/ml/ecos-discuss