This is the mail archive of the
ecos-discuss@sourceware.org
mailing list for the eCos project.
Re: How to connect RedBoot via Telnet running application
- From: "m mariga" <ma_ariga at yahoo dot co dot jp>
- To: "Gary Thomas" <gary at mlbassoc dot com>
- Cc: <ecos-discuss at ecos dot sourceware dot org>
- Date: Sat, 17 Oct 2009 00:50:14 +0900
- Subject: Re: [ECOS] How to connect RedBoot via Telnet running application
Hello,Gary,and everyone,
I am sorry I forgot ecos-discuss ,so I resend almost same mail.
Gary wrote
I'd like to connect to RedBoot via Telnet during target's running net
application.
I tried to run nc_test_slave program as application and connect to
RedBoot via Telnet from host's cygwin.
The result is below.
$ telnet 172.16.1.200 9000
Trying 172.16.1.200...
telnet: Unable to connect to remote host: Connection refused
<...snip>
Once your application is started, RedBoot is no longer available.
Why are you trying to do this?
I would like to load new application object to target using RedBoot via
Telnet from host PC during target's application running.
I also like to use RedBoot' monitor functions like "dump".
Is it impossible ?
I got an impression from Anthony J. Massa's book that if setted two
different IP addresses between RedBoot and application,I could connect to
RedBoot via Telnet during application running. Am I mistaken ?
m mariga
--
Before posting, please read the FAQ: http://ecos.sourceware.org/fom/ecos
and search the list archive: http://ecos.sourceware.org/ml/ecos-discuss